Wirelessly Tracking Interventional Medical Device with MRI System

Technology description

Interventional medical procedures can be performed less invasively, and more safely, when guided by magnetic resonance imaging (MRI). Placing devices like catheters, guidewires and stents using MRI guidance has great clinical potential.

One particular challenge in the field, however, has been the development of safe and reliable means for tracking such devices as they are manipulated within vessels or organs. Every previous approach has drawbacks. Attaching and tracking X-ray markers requires radiation, for example, while incorporating paramagnetic material into devices degrades image quality.

Another approach is to connect the devices with special coils that give feedback in real time. But blurry imaging is a problem. Also, cables have to extend from the tip of the device, out of the patient, and into an external connection. A new MRI tracking system needs to be more workable, clear and accurate. UW–Madison researchers have developed a method for driving and amplifying MR signals using an imaging coil that is coupled to a medical device and inserted into a subject. The position-tracking coil uses the MR system’s external radiofrequency pulses as a power source.

The coil switches between two duties: receiving and storing energy, and acquiring imaging data. Its signals can be wirelessly transmitted to the external MRI system using an amplifier and booster stages.
The Wisconsin Alumni Research Foundation (WARF) is seeking commercial partners interested in developing a method to transmit tracking and imaging signals from inside a patient using an internal coil powered by radiofrequency pulses.

Additional Information

For more information about MR-guided devices for tracking and imaging in 3-D, see WARF reference number P06222US.

http://www.warf.org/technologies/summary/P06222US.cmsx

Application area

  • MR-guided interventional procedures

Advantages

  • No cumbersome power source
  • Reduces the number of cables running to MRI scanner
  • Less radiation exposure to patient than in X-ray applications
  • Fewer adverse effects to patient from contrast agents than in X-ray applications

由于技术保密工作限制,技术信息无法完全展现,请通过邮箱或短信联系我们,获取更多技术资料。

More information

Categories
  • Diagnostic radiology
  • Medical instruments
Keywords:

great clinical potential

incorporating paramagnetic material

interventional medical procedures

internal coil powered

magnetic resonance imaging

下载 PDF 文档


感兴趣

Contact us

知繁业茂-yintrust logo知繁业茂-Branchly Innovation logo 知繁业茂-autmasia logo迈科技 logo