Novel Method to establish Backward Compatibility between Time Domain Optical Coherence Tomography (TDOCT) and Spectral Domain Optical Coherence Tomography (SDOCT)

Technology description

Background
Optical coherence tomography, which was developed in 1991 by D. Huang, et al at the Massachusetts Institute of Technology (MIT), Cambridge, is a low-coherence, interferometer-based, noninvasive medical imaging modality that can provide non-contact, high-resolution, cross-sectional images of biological tissue. The OCT product market is rapidly growing with more than 37,000 scans performed daily in the U.S. with OCT imaging systems. OCT can be divided into two different categories such as TDOCT (Time Domain Optical Coherence Tomography) and SDOCT (Spectral Domain Optical Coherence Tomography ). Recently, SDOCT is commercialized with high resolution and faster acquisition time compared with TDOCT. The multiple B-scans with SDOCT provide volumetric data, which can be used to visualize comprehensive structural information of the retina and retinal pathologies with 3D rendering software in ophthalmology. The quantitative analysis ability of OCT is essential, especially in glaucoma assessment. Retinal nerve fiber layer (RNFL) thickness measurements using repeated OCT B-scans on the same subject enable to track developmental changes with glaucoma, which is a leading cause of blindness. Follow-up scans are needed to detect RNFL thickness change, which takes months or years. However, there is no technology or methods, which provide backward compatibility between two-dimension (2D) TDOCT scan and three-dimension (3D) SDOCT volumetric data.TechnologyThis invention is a new technique to solve the backward compatibility problem between TDOCT devices (entrenched technology) and SDOCT devices (new technology with increasing market penetration). SDOCT has higher resolution and faster acquisition times in comparison to TDOCT. There is currently no technology / methodology to provide backward compatibility between two-dimensional (2D) TDOCT scans and three-dimensional (3D) SDOCT volumetric data.

Advantages

1) Enables maintainability of patient history baseline via seamless comparison of multi-device data (i.e. methodology allows SDOCT to locate the exact scan location of past 2D TDOCT cross-sectional image from 3D SDOCT volumetric data). Once a clinician knows the exact scan location, its possible to track, compare, and finally detect any abnormal retinal change over a long period of time without inter-device variation.
2) No other technology currently in existence that can provide backward compatibility between TDOCT & SDOCT.

由于技术保密工作限制,技术信息无法完全展现,请通过邮箱或短信联系我们,获取更多技术资料。

More information

Categories
  • Information technology
  • Diagnostic radiology
Keywords:

3d rendering software

quantitative analysis ability

backward compatibility problem

increasing market penetration

faster acquisition times

下载 PDF 文档


感兴趣

Contact us

知繁业茂-yintrust logo知繁业茂-Branchly Innovation logo 知繁业茂-autmasia logo迈科技 logo